3X3W_MR16低压射灯电源_620MA_9-11V

1X3W_MR16低压射灯电源_650MA_9-11V
1.2 电气规格
|
类 别 |
Item 项 目 |
技术指标 |
|
Input |
Voltage(输入电压范围) |
12/24V AC/DC |
|
Frequency(Hz) (输入频率范围) |
47-63 Hz |
|
|
Power Factor(功率因素) |
PF≥0.65 @Full Load and Typical Output Voltage |
|
|
Current(Full load) |
|
|
|
Output |
Constant current (恒流) |
620mA |
|
Current Accuracy(电流精度) |
±5% |
|
|
Voltage rang (输出电压范围) |
DC9-11V |
|
|
Load range(负载范围) |
9W |
|
|
Line Regulation(电压调整率) |
5% |
|
|
Load Regulation(负载调整率) |
5% |
|
|
Efficiency (效率) |
≥88% |
|
|
Protection |
Over Load |
110%rated output power |
|
Protection type: Auto recovery |
||
|
Over Voltage Protection |
13V |
|
|
Protection type :Auto recovery |
||
|
Short circuit Protection |
Protection type: Auto recovery |
|
|
Over Temperature |
OTP≥100± |
|
|
Protection type: Auto recovery |
||
|
Feature |
Dimension (尺寸) (T型) |
18mm*14mm |
|
Weight(重量) |
2.5g |
|
|
Isolation resistance |
Input-Output, Input-FG, Output-FG:100Mohms/500vdc/ |
|
|
Environment/life |
Operating Temperature(工作温度) |
|
|
Storage Temperature(存储温度) |
|
|
|
Temperature Coefficient(温度系数) |
±0.03%/℃(0 |
|
|
Humidity(湿度) |
10%-95%RH |
|
|
MTBF |
>30,000h @ |
|
|
Note |
1. 所有的参数无特别说明的都是在额定的输入交流230V和 2. 此精度包含了电压调整率、负载调整率以及设计误差。 3. 恒流模式仅适用于LED等相关行业。 |
|
二、测试数据
2.1 测试环境
测试设备: 测试环境温度:
|
类型 |
制造商 |
型号 |
|
示波器 |
UNI-T |
UT2102CE |
|
数字万用表 |
UNI-T、Fluke |
UT |
|
电参数测试仪 |
杭州远方仪器 |
PF9800 |
|
调压器 |
上海飘峰电器设备有限公司) |
TDGC2J-1 |
|
恒温恒湿箱 |
广州康恒仪器 |
101-D |
|
综合测试仪 |
杭州伏达仪器 |
UI-2000 |
2.2 测试原理图
2.3 测试数据
详细测试数据见附件:《LED驱动电源出货检验报告》
三、使用说明
本产品两端,一端为AC输入端,其中一端为输入“N”端;另一端为输入“L”端。
另一端为DC输出端,一端为DC输出负极,接“LED-”;另一端为DC输出正极,接“LED+”。
★★注1:在装置电源时,请注意输入、输出端的正确安接;
★★注2:为避免LED烧坏,请先接好DC输出端再开电源;
★★注3:使用本产品时请注意高压安全,并做好防电击措施。
四、非正常现象及相应的处理方法
1、电源在第一次装置好电气连接后,如出现不亮或其它相应现象时,请切断AC输入端并检查DC输出端有无接触不良或AC输入端有无接触不良;
2、在装置好电气连接后,并且LED灯点亮,但输出异常时,请切断AC输入端检查DC输出端有无过载、超载;
3、产品在使用过程当中如遇有疑问或解决不了问题请及时与我司沟通、反馈不良信息,以便我们提供更加优质的产品和服务。
LED电源咨询电话:13266660906 E-mail:info@dooyi.cn 联系人:曹先生